HomePageSitemap
    Italiano
ATCA TL-VDS600-14

 

DESCRIPTION

The TL-VDS600-14 is a 14-slots PICMG 3.0 AdvancedTCA compliant, designed and built for a central office environment.
AdvancedTCA defines a new equipment generation suitable for both Telecommunication and Data Processing applications.
TechnoLabs offers a family of optimized ATCA shelf, card controller, RTM modules and complete software solutions that allow a variety of architectural implementation.
The key benefits of the TechnoLabs ATCA platform include lower materials costs, faster time to market, and lower development costs.


14 ATCA SHELF

  • Compliance to the PICMG 3.0
  • 14 Slot Dual Star backplane
  • Dual Shelf manager
  • Dual 48V DC input terminals
  • 2xPEM (Power Entry Module)
  • Alarm Panel
  • 3x pluggable removable fan trays
  • 1x air filtering
  • Advanced front to rear cooling
  • RTM Modules


ATCA Performance

The high frequency signal routing between slots on the backplane , requires clear signal transmission without compromising the system stability.
TechnoLabs uses advanced techniques of simulation (design and thermal) to avoid causes which can degrade the signal quality.

- Backplane

The TL-VDS600-14 backplane supports a maximum of 14 slots in Dual Star Topology where a pair of Hub Boards provides redundant interconnects between node boards with signal speeds up to 3.125 Gbps.
Star Topologies are commonly referred to as point-to-point and point-to-multipoint networks.
The backplane includes :

  • Base Interface
  • Fabric Interface
  • Update Channel Interface
  • Synchronization Clock Interface
  • IPMB bus


- Power Distribution

The TL-VDS600-14 system , according to the ATCA standards, is capable of dissipating as much power as 200W per single-slot. The system is powered by two redundant primary 48V power feeds. Power is provided by power connectors mounted on the two rear PEMs.
The TL-VD600-14 also performs the necessary emissions filtering functions as required in the PICMG3.0 specification to meet the requirements for conducted and radiated emissions.


- System Management

The TL-VDS600-14 provides an intelligent system management responsible of the health status and correct functionality of the whole shelf.
The control is based on a couple redundant of shelf manager cards. These cards talk with the IPMC controllers (Intelligent Platform Management Controller) distributed on each board that can be equipped in the shelf using dual Intelligent Platform Management Bus (IPMB).


- Telco Alarms

The TL-VDS600-14 provides standard telecom alarms. The Critical, Major, Minor and Power conditions are provided by the Alarm Unit FRU.


- Software

The Basic Software on the ATCA system is based on the operating system LINUX with additional system related services.
A Web interfaces with protected access is also provided.


DETAIL SPECIFICATIONS

- Physical

  • For vertical solutions, rack of 600mm depth
  • Slot dimension: 6HP (30,48mm)
  • Max pluggable cards number for vertical applications:14 for 19”, 23” and 600X600 ETSI racks

- Power

  • Dual Redundant PEM (Power Entry Module). Power inputs: 48VDC
  • Each slots receive, via backplane, redundant power supply lines
  • 3 LEDs on the PEM front panel under ShMC control, which indicate: Hot swap (blue), Failure (red) and power-on (grn)
  • Full power to dissipate: 2800W (200Wx14slots)

- Thermal management

  • 3 FAN units (2 FANs for each tray)
  • Air temperature increasing between input and output < 20°C
  • Temperature detectors for FAN speed control
  • Air filtering

- Backplane

  • Dual star topology
  • Dual redundant IPMBuses

- Shelf Alarms LEDs and Facilities

  • Telco alarms
  • Hot swap, Failure and Power-on LEDs
  • Alarms acknowledgement button

- EMC /Environment

  • (TS 61587-3 level 2)
  • RoHS and WEEE Compliant
Physical
Dimension
12U(H)x482(W)x476(D) mm
material Stainless steel
compliance PICMG 3.0
Power
DC Input
-48 VDC/-60 VDC (Nominal)
Redundancy
Dual redundant PEM modules, either capable of supplying 100% of shelf power
Cooling Num. of fans
6 (3 trays with 2 fans for each)
Redundancy
N+1(one fan can fail with no service degradation)
Fan speed
Temperature-based variable speed control
Cooling capacity
200W per slot, 2800W per shelf
Backplane
Signal speeds
3.125 Gbps
Node slots
12
Hub slots
2
Fabric interconnect
Base interface (1 port) plus fabric interface (4 ports) dual star interconnection to all slots
Update channels
Between fabric slots (7-8) and node slot pairs (1-2, 3-5, 4-6, 9-11, 10-12, 13-14)
IPMB support
Dual redundant IPMBusses to all slots.
IPMB extension also provided.
Alarm I/O
Alarm I/O interfaces
15-pin SUB-D connector supporting 4 outputs (Major, Minor, Critical, Power) and 2 inputs (Major & Minor Reset).
25-pin SUB-D connector supporting Ringing Bus and metallic test bus.
Shelf Peripherals
Managed IPMI Peripherals
shelf FRU (Field Replaceable Unit)
EPROM
LEDs and Facilities
LEDs
Critical (Red), Major (Red/Yel), Minor (Amber), Power Good (Grn)
Audible alarm
Silenced via alarm acknowledge button
Regulatory Safety
EN60950
EMC IEC TS 61587-3 LEVEL 2
Environment
ETSI ETS 300 019-1-1: storage class 1.2 for non-temp-controlled locations
ETSI ETS 300 019-1-2: transp. class 2.3 except for rain requirement
ETSI ETS 300 019-1-3: prA1 earthquake response spectrum, /A1 operating class 3.1 for temp-controlled locations
ETSI ETS 300 753: acoustic noise for env. class 3.1 non-office environments

 

 
         
Compel Group


HomePage - Sitemap
ABOUT US: Compel Group Overview - Compel Group Structure - Quality Policy
MAIN MARKETS : Wireless TLC - Wireline TLC - Mobile - Defense - Utilities
PRODUCTS AND SERVICES :  Equipment - Subsystems - Interconnection Components - R&D Service -Technical Service
CAPABILITIES : R&D Team - Technologies - New Product Introduction - Assembling - Testing
NEWS : News - News Archive